| Product Specifications |
| Dimensions and Mass |
190 (W)mm x 96 (H)mm x 48 (D)mm (7.5”x3.8”x1.9”) (Including mainframe and module)
Weight (including mainframe, module and battery): <800 g (<2 lbs.) |
| Display |
4.3 inch TFT-LCD (480x272, with backlight, transparent type) |
| Interface |
USB 1.1, Type A x1 (memory), Type B x 1 (USB mass storage) |
| Model |
MU909011A, A1, A2, A3-052/062MU909011A, A1, A2, A3-050/060 |
| Wavelength +1 |
780±20 nm 1550±30 nm |
| Fiber Type |
10/125 um SMF (ITU-T G.652) |
| Distance Range |
1.0 km (3,000 ft) or 2.5 km (8,000 ft)
set automatically
1.0 km (3,000 ft), 2.5 km (8,000 ft) or 10 km (32,000 ft)
set automaticallly
|
| Pulse width |
<10 ns |
| Dynamic Range +2 |
>7.0 dB |
| Deadzone |
Fresnel: <1 m+3, Backscatter: <5 m+4 |
| Sampling Resolution |
5 cm (Distance range 1.0 km), 10 cm (Distance range 2.5 km) (IOR=1.50000) |
| Sampling Points |
20001 (Distance range 1.0 km), 25001 (Distance range 2.5 km) |
| Data Storage |
Internal memory:40 MB (up to 800 traces), External (USB): up to 20,000 traces with 1GB |
| IOR Setting |
1.3000 to 1.7000 (0.0001 steps) |
| Units |
ft, m |
| Fiber Event Analysis |
Automatic, displayed in table format based on user defined PASS/FAIL thresholds |
| Loss Modes |
2 point loss, dB/km |
| OTDR Trace Format |
Telcordia universal (.SOR), issue 2 (SR-4731) |
| Other Functions |
Integrated launch fiber: 10 m (30 ft) |
| Connector Inspection Microscope (Optional); verifies connector condition and clealiness |
| Connection check: Automatic check of OTDR to FUT connection quality |
| Live Fiber detect : verifies presence of communication light in optical fiber |
| Real time sweep: <1sec (typical) |
| Languages |
Spanish, French, German, Italian, Simplified Chinese, Traditional Chinese and English |
Integrated Optical Power Meter
(Optional)
|
Wavelength 1550 nm, same port as OTDR |
| Power range:5 to 45 dBm, Accuracy:±0.5 dB*5, Maximum input:+10 dBm |
| Visible Laser Diode (Optional) |
Connector: 2.5 mm universal, Wavelength: 650±15 nm, Output: 0±3 dBm Laser safety: IEC Pub 60825-1: 2001
Class3R: MU909011A1/A3-050/060/052/062*9 (CW)
|
| Power Supply |
9 VDC, 100 to 240 VAC, Allowable input voltage range: 90 to 264 V, 50/60 Hz |
| Battery |
NiMH, Operating Time: 3.5 hours (typical)*6, Recharge Time:<3 h*7 |
| Environmental Conditions |
Operation: 0º to +50ºC, <80% (non-condensing)*8, Storage: 20º to +60ºC |
| Vibration: MIL-T-28800E Class 3, Dust and Drip proof: IP 51 |
| EMC |
EN61326 |
| Laser safety |
IEC Pub 60825-1: 2001 Class1: MU909011A/A1/A2/A3-050/060/052/062*10 |
Follow us on